装配式洁净室的安装
发布人:发布时间2018-09-19浏览次数:0

    1、装配式洁净室的安装,应在装饰工程完成后的室内进行。室内空间必须清洁、无积尘,并在施工安装过程中对零部件和场地随时清扫、擦净。

    1. The installation of fabricated clean rooms should be carried out indoors after the decoration works are completed. The indoor space must be clean and free from dust accumulation. During the process of construction and installation, parts and sites should be cleaned and cleaned at any time.

    2、施工安装时,应首先进行吊挂、锚固件等与主体结构和楼面、地面的联结件的固定。

    2. During construction and installation, the hangers, anchors, etc. should be fixed to the main structure and the connection between the floor and the ground.

    3、地面面层必须平整,其不平整度不应大于0.2%。在做卷材面层或涂料面层时应考虑与垂直壁板交接处的密封。

    3, the ground surface must be leveled, and its roughness should not be greater than 0.2%. When making coil surface or coating surface, the sealing should be considered at the junction with vertical wall panels.

    4、壁板安装前必须严格放线,墙角应垂直交接,防止累积误差造成壁板倾斜扭曲,壁板的垂直度偏差不应大于0.2%。

    4, before the wall panel installation must be rigorously placed, the wall angle should be vertically connected to prevent the cumulative error caused by the wall skew distortion, the perpendicularity of the panel should not be more than 0.2%.

    5、吊顶应按房间宽度方向起拱,使吊顶在受荷载后的使用过程中保持平整。吊顶周边应与墙体交接严密。

    5. The ceiling should be arched according to the width of the room, so that the ceiling will be kept smooth during the use of the load. The wall of the ceiling should be closely connected with the wall.

    6、安装过程中不得撕下壁板表面塑料保护膜,禁止撞击和踩踏板面。

    6. During installation, the plastic protective film on the panel should not be ripped off, and the impact and pedal should be prohibited.

    7、各种构配件和材料应存放在有围护结构的清洁、干燥的环境中,平整地放置在防潮膜上。

    7, all kinds of structural parts and materials should be stored in a clean and dry environment with enclosure structure, and placed on the moistureproof membrane evenly.

    8、构配件和材料的开箱启封应在清洁环境中进行,应严格检查其规格性能和完好程度,不合格或已损坏的构配件严禁安装。

    8. The opening and opening of the components and materials should be carried out in a clean environment. The specifications and performance and the degree of integrity should be strictly checked. The unqualified or damaged parts and fittings should be strictly prohibited.

    9、需要粘贴面层的材料、嵌填密封胶的表面和沟槽必须严格清扫清洗,除去杂质和油污,确保粘贴密实,防止脱落和积灰。

    9, the material that needs to paste the surface layer, the surface and groove of embedded sealant must be cleaned and cleaned strictly, remove impurities and oil pollution, ensure the stickup and dense, prevent falling off and ash.

    10、装配式洁净室的安装缝隙,必须用密封胶密封。

    10. The installation gap of the fabricated clean room must be sealed with sealant.

    本文由济南办公写字楼装修提供帮助,更多的相关内容请点击:http://www.chinazhuoyou.com我们将详情为您解答.欢迎您的光临!


上一篇:银行装修特点
下一篇:幼儿园装修参考标准
相关文章

版权所有:济南金派装饰工程有限公司  电话:0531-82826738
联系地址:山东省济南市高新区舜泰广场6号楼2501E   备案号:鲁ICP备17026442号-1